PX-Gateway

The PX-Gateway is the gateway device that collects data from all nearby sensors and transmits it to the PrecastX Cloud.


Specifications

ParameterValue
Communication
Sensor ProtocolESP-NOW
Sensor CapacityUp to 20 simultaneous
Sensor Range100m indoor / 300m outdoor
Cloud ConnectionWiFi 2.4GHz or 4G LTE
BluetoothBLE 5.0 (for configuration)
Data
Local Buffer7 days of data
Upload IntervalReal-time (configurable)
Power
InputUSB-C 5V/2A or 12-24V DC
Consumption2W typical
Battery Backup4 hours (internal)
Physical
Dimensions150 × 100 × 45 mm
Weight280g
EnclosureABS plastic, IP54
Operating Temp-20°C to +50°C
MountingWall mount or DIN rail

Initial Setup

1. Power On

Connect the 12V DC adapter or USB-C power cable. The device boots automatically. During cellular registration the firmware shows LED 1 orange blinking; MQTT setup then uses LED 1 cyan breathing until the cloud session is up.

2. Connect via Mobile App

  1. Open PrecastX app → Devices tab
  2. Tap on the gateway in the "Nearby" section
  3. Follow the on-screen WiFi configuration wizard

3. Configure WiFi

Enter your facility's WiFi credentials:

  • Network name (SSID)
  • Password
  • The gateway will test connectivity and confirm

LED Indicators

These are the LED states that matter in normal use:

LEDColorPatternMeaning
LED 1🔴Fast blinkCellular connection lost
LED 1Solid (dim)Gateway is powered on and idle
LED 2🟠BreathingBackup battery is charging
LED 2🟢SolidBackup battery is fully charged
LED 3🔵SolidConnected to the mobile app over Bluetooth
All LEDs🟠BlinkingShutdown pending; release the power button to turn the gateway off

Deployment Guidelines

Placement

  • Mount at a central location within your facility
  • Elevate at least 2m from ground for best range
  • Avoid placement inside metal enclosures
  • Keep away from large metal structures that block radio signals

Range Considerations

EnvironmentTypical Range
Open outdoor300m
Warehouse (high ceiling)150m
Indoor with walls100m
Through concrete walls30-50m

Multiple gateways

For large facilities, deploy multiple gateways:

  • Each covers a zone of your facility
  • Sensors automatically connect to the strongest signal
  • All data aggregates in the cloud seamlessly

Network Configuration

Firewall Requirements

Ensure the following outbound connections are allowed:

ServiceProtocolPortDomain
MQTTTLS8883mqtt.precastx.com
HTTPSTLS443api.precastx.com

Static IP (Optional)

If your network requires static IP configuration, use the Mobile App:

  1. Connect to gateway via Bluetooth
  2. Go to SettingsNetworkAdvanced
  3. Toggle off "DHCP" and enter IP settings

Offline Operation

If internet connectivity is lost:

  • Data continues to be collected from sensors
  • Up to 7 days of data is stored locally
  • When connectivity returns, buffered data is uploaded automatically
  • LED 1 shows cyan breathing while the MQTT client reconnects, and fast red blinking on LED 1 if the cellular modem loses its bearer entirely

Maintenance

Firmware Updates

Updates are delivered automatically over-the-air when connected to the internet. You'll see a notification in the Web Dashboard when updates are applied.

Factory Reset

If needed, reset to factory defaults:

  1. Power off the device
  2. Press and hold the power button
  3. While holding, reconnect power
  4. Continue holding for 10 seconds
  5. LED will flash rapidly, then device reboots